This Practice provides requirements for design and manufacture of horizontal centrifugal pumps of 150 kW (200 HP) or greater used for general water services.
Comment: General water services include condensate, cooling water, demineralized water, utility water, produced water, treated water, etc.
This Practice covers pumps with service conditions within the following limits: a. Maximum discharge pressure 35 Barg (500 psig) b. Minimum pumping temperature 0C (32F) c. Maximum pumping temperature 150C (300F) d. Maximum rotational speed 3,600 rpm
Comment: For services within the capabilities of ANSI/ASME pumps, use PIP RESP73H.
Pump types covered by this Practice are broadly classified as overhung or between-bearings. The following pump types are not included in the scope of this Practice: a. Close coupled (i.e., impeller mounted on the motor shaft) b. Two-stage overhung c. Double suction overhung
Fire water pumps are covered by NFPA 20 and are not covered by this Practice.
Product Details
Published: 01/01/2020 Number of Pages: 31 File Size: 1 file , 620 KB